Check the pump test yourself, point by point.
Rated Point is independent pump factory test verification software for the witness engineer. Type the readings at the test bed. It corrects every point, draws the curves live and checks acceptance against API 610, ISO 9906, HI 14.6 and NFPA 20.
From the first reading to the signed report
Each point is corrected on its own as you type: its own speed, water temperature and motor load. The curves draw while you are still standing at the pump.
Before the test
Datasheet, liquid, test bed and driver. The program shows the correction plan and the acceptance limits in numbers.
During the test
Type readings line by line. Problems show as alarms; nothing ever blocks your work.
After the test
Results before and after correction, acceptance, curves, and a PDF report in English or Arabic with signature boxes.
Every test of a pump factory acceptance, in one program
One calculation engine behind every screen and the report, so the number you see is the number that prints.
Performance
Corrected to rated speed and site liquid. The R point is read from the corrected curves at exactly the rated flow.
NPSH
NPSH3 at 3 % head drop per flow, with API 610 rules, and the NPSH3 curve against flow.
Trim analysis
The impeller diameter that meets the duty point, with every check before and after the trim.
Mechanical run
Bearing temperature and vibration over time, with limits from the standard or the contract.
Viscosity and vertical pumps
HI 9.6.7 viscosity correction, and column loss for vertical pumps tested with a shorter column.
Compare up to 15 pumps
Table and overlaid curves, failed checks in red. Made for twin pumps and re-tests.
Also: Curves with a reader for any point, Future upgrade for what-if studies, Test simulation, motor and instrument lists, and an alarm when an instrument's calibration has expired.
The standards it checks against
Every tolerance comes from the standards library, and a customer tolerance can replace it for one test.
- API 61011th and 12th edition
- ISO 99061B · 1E · 1U · 2B · 2U · 3B
- HI 14.61B · 1E · 1U · 2B · 2U · 3B
- NFPA 202025, fire pump checks
- HI 9.6.7Viscosity correction
Your data stays on your computer
Tests, the library and backups are stored only on your device. The program does not send your test data anywhere.
At the test bed, without internet
Windows on a laptop or Android on a tablet. Works fully offline.
Try it before launch
We are picking a small group of witness and inspection engineers to use the beta in December and tell us what they think. Or leave your email and we will tell you the day it launches.
We use your email only for the beta and the launch. Ask us to delete it at any time.